5.5med

CVE-2019-6567

A vulnerability has been identified in SCALANCE X-200 switch family (incl.

Published 7 y ago · modified 4 mo ago · JSON

CVSS
5.5
v3.1 · NVD
CISA KEV
No
not known exploited
EPSS
0.3%
percentile 23%
Public exploits
0
none known

Summary

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions < V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords.

Exploit prediction (EPSS)

0.30% probability of exploitation in the next 30 days, higher than 23% of all scored CVEs.

CVSS scores

Assigned byVersionScoreVector
NVD3.15.5CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
NVD2.02.1AV:L/AC:L/Au:N/C:P/I:N/A:N

Affected products

  • Siemens SCALANCE X-200 switch family (incl. SIPLUS NET variants)
  • Siemens SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)
  • Siemens SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)
  • Siemens SCALANCE X-414-3E

Classification

Weakness
  • CWE-257 Storing Passwords in a Recoverable Format
  • CWE-522 Insufficiently Protected Credentials

References

Sources

vulnwire keeps one entry per vulnerability: the CVE id wins, then GHSA; records that alias each other are merged. Machine-readable: JSON.