5.3med
CVE-2019-5643
C4G BLIS Improper Access Control
Published 7 y ago · modified 4 mo ago · JSON
CVSS
5.3
v3.1 · CNA
CISA KEV
No
not known exploited
EPSS
0.9%
percentile 60%
Public exploits
0
none known
Summary
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.5 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may enumerate the user names and facility names in use on a particular installation.
Exploit prediction (EPSS)
0.90% probability of exploitation in the next 30 days, higher than 60% of all scored CVEs.
CVSS scores
| Assigned by | Version | Score | Vector |
|---|---|---|---|
| CNA | 3.1 | 5.3 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N |
| CNA | 3.1 | 5.3 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N |
| NVD | 3.1 | 5.3 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N |
| NVD | 2.0 | 5.0 | AV:N/AC:L/Au:N/C:P/I:N/A:N |
Affected products
- Computing For Good Basic Laboratory Information System
Classification
References
- blog.rapid7.com /2019/09/10/r7-2019-09-cve-2019-5617-cve-2019-5643-cve-2019-5644-c4g-blis-authentication-a · x_refsource_MISC, x_transferred
Sources
- CVE List: CVE-2019-5643
- NVD: CVE-2019-5643