4.8med

CVE-2018-4842

A vulnerability has been identified in SCALANCE X-200IRT switch family (incl.

Published 8 y ago · modified 4 mo ago · JSON

CVSS
4.8
v3.0 · NVD
CISA KEV
No
not known exploited
EPSS
0.8%
percentile 58%
Public exploits
0
none known

Summary

A vulnerability has been identified in SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). A remote, authenticated attacker with access to the configuration web server could be able to store script code on the web site, if the HRP redundancy option is set. This code could be executed in the web browser of victims visiting this web site (XSS), affecting its confidentiality, integrity and availability. User interaction is required for successful exploitation, as the user needs to visit the manipulated web site. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.

Exploit prediction (EPSS)

0.83% probability of exploitation in the next 30 days, higher than 58% of all scored CVEs.

CVSS scores

Assigned byVersionScoreVector
NVD3.04.8CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
NVD2.03.5AV:N/AC:M/Au:S/C:N/I:P/A:N

Affected products

  • Siemens SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)
  • Siemens SCALANCE X-200RNA switch family
  • Siemens SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)

Classification

Weakness
  • CWE-79 Improper Neutralization of Input During Web Page Generation

References

Sources

vulnwire keeps one entry per vulnerability: the CVE id wins, then GHSA; records that alias each other are merged. Machine-readable: JSON.