6.7med

CVE-2018-0088

A vulnerability in one of the diagnostic test CLI commands on Cisco Industrial Ethernet 4010 Series Switches running Cisco IOS Software cou…

Published 8 y ago · modified 4 mo ago · JSON

CVSS
6.7
v3.0 · NVD
CISA KEV
No
not known exploited
EPSS
0.4%
percentile 33%
Public exploits
0
none known

Summary

A vulnerability in one of the diagnostic test CLI commands on Cisco Industrial Ethernet 4010 Series Switches running Cisco IOS Software could allow an authenticated, local attacker to impact the stability of the device. This could result in arbitrary code execution or a denial of service (DoS) condition. The attacker has to have valid user credentials at privilege level 15. The vulnerability is due to a diagnostic test CLI command that allows the attacker to write to the device memory. An attacker could exploit this vulnerability by authenticating to the targeted device and issuing a specific diagnostic test command at the CLI. An exploit could allow the attacker to overwrite system memory locations, which could have a negative impact on the stability of the device. Cisco Bug IDs: CSCvf71150.

CISA SSVC assessment

Exploitation
none
Automatable
no
Technical impact
total
Assessed
23 mo ago

Exploit prediction (EPSS)

0.39% probability of exploitation in the next 30 days, higher than 33% of all scored CVEs.

CVSS scores

Assigned byVersionScoreVector
NVD3.06.7CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
NVD2.07.2AV:L/AC:L/Au:N/C:C/I:C/A:C

Affected products

  • n/a Cisco IOS

Classification

Weakness
  • CWE-399 Resource Management Errors
  • CWE-732 Incorrect Permission Assignment for Critical Resource

References

  • tools.cisco.com /security/center/content/CiscoSecurityAdvisory/cisco-sa-20180117-iess · x_refsource_CONFIRM, x_transferred
  • securitytracker.com /id/1040240 · vdb-entry, x_refsource_SECTRACK, x_transferred

Sources

vulnwire keeps one entry per vulnerability: the CVE id wins, then GHSA; records that alias each other are merged. Machine-readable: JSON.