CVE-2017-9855
An issue was discovered in SMA Solar Technology products.
Published 9 y ago · modified 4 mo ago · JSON
Summary
An issue was discovered in SMA Solar Technology products. A secondary authentication system is available for Installers called the Grid Guard system. This system uses predictable codes, and a single Grid Guard code can be used on any SMA inverter. Any such code, when combined with the installer account, allows changing very sensitive parameters. NOTE: the vendor reports that Grid Guard is not an authentication feature; it is only a tracing feature. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
CISA SSVC assessment
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
- Assessed
- 2 y ago
Exploit prediction (EPSS)
1.58% probability of exploitation in the next 30 days, higher than 76% of all scored CVEs.
CVSS scores
| Assigned by | Version | Score | Vector |
|---|---|---|---|
| CISA ADP | 3.1 | 9.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| CNA | 3.1 | 9.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| NVD | 3.0 | 9.8 | CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| NVD | 2.0 | 7.5 | AV:N/AC:L/Au:N/C:P/I:P/A:P |
Affected products
- sma sunny_boy_3600_firmware
- sma sunny_boy_5000_firmware
- sma sunny_tripower_core1_firmware
- sma sunny_tripower_15000tl_firmware
- sma sunny_tripower_20000tl_firmware
- sma sunny_tripower_25000tl_firmware
- sma sunny_tripower_5000tl_firmware
- sma sunny_tripower_12000tl_firmware
- sma sunny_tripower_60_firmware
- sma sunny_boy_3000tl_firmware
- sma sunny_boy_3600tl_firmware
- sma sunny_boy_4000tl_firmware
- sma sunny_boy_5000tl_firmware
- sma sunny_boy_1.5_firmware
- sma sunny_boy_2.5_firmware
- sma sunny_boy_3.0_firmware
- sma sunny_boy_3.6_firmware
- sma sunny_boy_4.0_firmware
- sma sunny_boy_5.0_firmware
- sma sunny_central_2200_firmware
- sma sunny_central_1000cp_xt_firmware
- sma sunny_central_800cp_xt_firmware
- sma sunny_central_850cp_xt_firmware
- sma sunny_central_900cp_xt_firmware
- sma sunny_central_500cp_xt_firmware
- sma sunny_central_630cp_xt_firmware
- sma sunny_central_720cp_xt_firmware
- sma sunny_central_760cp_xt_firmware
- sma sunny_central_storage_500_firmware
- sma sunny_central_storage_630_firmware
- sma sunny_central_storage_720_firmware
- sma sunny_central_storage_760_firmware
- sma sunny_central_storage_800_firmware
- sma sunny_central_storage_850_firmware
- sma sunny_central_storage_900_firmware
- sma sunny_central_storage_1000_firmware
- sma sunny_central_storage_2200_firmware
- sma sunny_central_storage_2500-ev_firmware
- sma sunny_boy_storage_2.5_firmware
Classification
- Weakness
- CWE-863 Incorrect Authorization
References
- sma.de /en/statement-on-cyber-security.html · x_refsource_MISC, x_transferred
- horusscenario.com /CVE-information/ · x_refsource_MISC, x_transferred
- sma.de /fileadmin/content/global/specials/documents/cyber-security/Whitepaper-Cyber-Security-AEN1 · x_refsource_MISC, x_transferred
Sources
- CVE List: CVE-2017-9855
- NVD: CVE-2017-9855