CVE-2017-9852
An Incorrect Password Management issue was discovered in SMA Solar Technology products.
Published 9 y ago · modified 4 mo ago · JSON
Summary
An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. NOTE: the vendor reports that it has no influence on the allocation of passwords, and that global hardcoded master passwords do not exist. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
Exploit prediction (EPSS)
1.72% probability of exploitation in the next 30 days, higher than 78% of all scored CVEs.
CVSS scores
| Assigned by | Version | Score | Vector |
|---|---|---|---|
| NVD | 3.0 | 9.8 | CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| NVD | 2.0 | 5.0 | AV:N/AC:L/Au:N/C:P/I:N/A:N |
Classification
- Weakness
- CWE-798 Use of Hard-coded Credentials
References
- sma.de /en/statement-on-cyber-security.html · x_refsource_MISC, x_transferred
- horusscenario.com /CVE-information/ · x_refsource_MISC, x_transferred
- sma.de /fileadmin/content/global/specials/documents/cyber-security/Whitepaper-Cyber-Security-AEN1 · x_refsource_MISC, x_transferred
Sources