4.0med
CVE-2016-7090
The integrated web server on Siemens SCALANCE M-800 and S615 modules with firmware before 4.02 does not set the secure flag for the session…
Published 10 y ago · modified 4 mo ago · JSON
CVSS
4.0
v3.0 · NVD
CISA KEV
No
not known exploited
EPSS
1.9%
percentile 80%
Public exploits
0
none known
Summary
The integrated web server on Siemens SCALANCE M-800 and S615 modules with firmware before 4.02 does not set the secure flag for the session cookie in an https session, which makes it easier for remote attackers to capture this cookie by intercepting its transmission within an http session.
Exploit prediction (EPSS)
1.90% probability of exploitation in the next 30 days, higher than 80% of all scored CVEs.
CVSS scores
| Assigned by | Version | Score | Vector |
|---|---|---|---|
| NVD | 3.0 | 4.0 | CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:N/A:N |
| NVD | 2.0 | 4.3 | AV:N/AC:M/Au:N/C:P/I:N/A:N |
Classification
- Weakness
- CWE-200 Exposure of Sensitive Information to an Unauthorized Actor
References
- ics-cert.us-cert.gov /advisories/ICSA-16-271-01 · x_refsource_MISC, x_transferred
- siemens.com /cert/pool/cert/siemens_security_advisory_ssa-342135.pdf · x_refsource_CONFIRM, x_transferred
- securityfocus.com /bid/93115 · vdb-entry, x_refsource_BID, x_transferred
Sources
- CVE List: CVE-2016-7090
- NVD: CVE-2016-7090
vulnwire keeps one entry per vulnerability: the CVE id wins, then GHSA; records that alias each other are merged. Machine-readable: JSON.